Breathing Air Compressors
High Air HX series breathing air compressor is designed to be reliable, durable, easy to maintain, and energy-efficient. It finds wide applications in firefighting, diving, personal protection, and rescue fields.¡£
For different applications, we can provide flow ranging from 80L/min to 2800L/min, with a maximum filling pressure of up to 400 BAR. We offer both portable and silent compressors for inflation stations, along with containment fill station, control panels, gas storage systems, and testing systems, catering to your diverse needs. Our goal is to provide you with a one-stop solution to meet all your requirements.
The quality of breathing air directly affects the health of the users. We ensure that every compressor is equipped with an air purification system, and the quality of the outlet air meets and exceeds the EN 12021 breathing air standard. This guarantees that we provide you with clean and safe air, ensuring the well-being and safety of the users.
EN 12021:2014 | REQUITMENTS |
Oxygen(O2) | 21%Ê¿1% |
Carbon monoxide(CO) | 15ppm |
Carbon dioxide(CO2) | 500ppm |
oi | 0.5mg/m3 |
H2O | 25mg/m3 |
Portable Breathing Air Compressors
The HX125 series portable breathing aircompressors,compact structure, strong durability, light weight, easy to move, widely used in the fields of firefighting, diving, and rescue.
¡ñ Steelbase-plate, high -strength ABS belt protective cover, providing all-round protection.
¡ñ Arc-shaped handle, easy holding and carrying.
¡ñ Motor and gasoline driven optional.
¡ñ Three-phase motor version with a magnetic starter and pressure switch, auto stop.
¡ñ The motor driven with 3 meters power line, industrial plug and socket, hat is, plug and play.
¡ñ The gasoline engine driven has an extended intake pipeline to prevent gasoline engine emission pollution.
¡ñ Three-stage design block, with stainless steel coolers.
¡ñ Over sized breathing air filter to meet breathing standards EN12021.
¡ñ 225BAR/330BAR optional
¡ñ Pressure maintaining valve.
¡ñ One filling valve with pressure gauge.
Model | Driven | Charging Rate l/min | Pressaure Bar | Filling valve | Dimensions mm | Weight kg |
HX125E | 380/3/50 3KW motor | 125 | 225/330 | 1 | 706*376*432 | 49 |
HX125M | 220/1/50 3KW motor | 125 | 225/330 | 1 | 706*376*432 | 52 |
HX125G | 5.5HP gasolinel Engine | 125 | 225/330 | 1 | 706*408*432 | 47 |
Charging rate is measured by cylinder(10L) from 0-200Bar+/-5%. |
¡ñ Steelbase-plate, high-strength ABS belt protective cover, providing all-round protection.
¡ñ Arc-shaped handle, easy holding and carrying.
¡ñ Motor and gasoline driven optional.
¡ñ Three-phase motor version with a magnetic starter and pressure switch, Auto stop
¡ñ The motor driven with 3 meters power line, industrial plug and socket, that is, plug and play.
¡ñ The gasoline engine driven has an extended intake pipeline to prevent gasoline engine emission pollution.
¡ñ Three-stage block, with stainless steel coolers.
¡ñ Over sized breathing air filter to meet breathing standards EN12021.
¡ñ 225BAR/330BAR optional.
¡ñ Pressure maintaining valve and check valve.
¡ñ Two Filling valves with hoses.
Model | Driven | Charging Rate l/min | Pressure Bar | Filling valve | Dimensions mm | Weight kg |
HX235E | 380/3/50 4KW motor | 235 | 225/330 | 2 | 975*508*700 | 118 |
HX235M | 220/1/504KW motor | 235 | 225/330 | 2 | 975*508*700 | 122 |
HX235G | 9.5HP gasoline engine | 235 | 225/330 | 2 | 1065*508*700 | 123 |
HX300E | 380/3/505.5kW motor | 300 | 225/330 | 2 | 975*508*700 | 125 |
HX300G | 9.5HP gasoline engine | 300 | 225/330 | 2 | 1065*508*700 | 128 |
HX345E | 380/3/50 7.5KW motor | 345 | 225/330 | 2 | 975*508*700 | 130 |
HX345G | 9.5HP gasoline engine | 345 | 225/330 | 2 | 1065*508*700 | 128 |
1.Charging rate is measured by cylinder(10L) from 0-200Bar,+/-5%. 2.Gasoline engine driven is manual control. 3.Handles are not included in the dimensions.The length is 1250mm with handles. |
Integrated Breathing Air Compressords
¡ñ High strength aluminum alloy frame, ABS belt protective cover, providing all-around protection.
¡ñ Arc-shaped handle, easy holding and carrying.
¡ñ Motor and gasoline driven optional.
¡ñ Automatic condensate drain and sewage collection system, Clean and environmentally friendly.
¡ñ Different control systems optional B-Electric control,with pressure switch ,auto stop.C-PLC control,with pressure sensor,auto start/stop.
¡ñ The motor driven with 3 meters power line, industrial plug and socket, that is, plug and play.
¡ñ The gasoline engine driven has an extended intake pipeline to prevent gasoline engine emission pollution.
¡ñ Three-stage design block, with stainless steel coolers.
¡ñ Over sizedd breathing air filter to meet breathing standards EN12021.
¡ñ 225BAR/330BAR optional.
¡ñ Pressure maintaining valve and check valve.
¡ñ Two Filling valves with hoses.
¡ñ Wheels optional.
Model | Driven | Charging Rate l/min | Pressure Bar | Filling valve | Control | Dimensions mm | Weight kg |
HX235ET | 380/3/50 4KW motor | 235 | 225/330 | 2 | B/C | 1228*593*714 | 126 |
HX235MT | 220/1/50 4kW motor | 235 | 225/330 | 2 | B/C | 1228*593*714 | 130 |
HX235GT | 9.5HP gasoline | 235 | 225/330 | 2 | Manual | 1228*593*714 | 123 |
HX300ET | 380/3/505.5KW motor | 300 | 225/330 | 2 | B/C | 1228*593*714 | 133 |
HX300GT | 9.5H gasoline | 300 | 225/330 | 2 | Manual | 1228*593*714 | 123 |
HX345ET | 380/3/50 7.5kW motor | 345 | 225/330 | 2 | B/C | 1228*593*714 | 138 |
HX345GT | 14HP gasoline | 345 | 225/330 | 2 | Manual | 1228*593*714 | 128 |
HX385ET | 380/3/50 7.5KW motor | 385 | 225/330 | 2 | B/C | 1228*593*714 | 140 |
HX385GT | 14HP gasoline | 385 | 225/330 | 2 | Manual | 1228*593*714 | 130 |
1. Charging rate is measured by cylinder(10L) from 0-200Bar+/-5%. 2. Gasoline engine driven is manual control. |
Silent Breathing Air Compressors
¡ñVertical design, small footprint.
¡ñSuper silent design, noise lever less than 70dBA.
¡ñAutomatic condensate drain and sewage collection system, Clean and environmentally friendly.
¡ñAutomatic PLC control system with touch screen.
¡ñFilling port for cylinder groups filling with valve optional.
¡ñOver sized breathing air filter to meet breathing standards EN12021.
¡ñ 225BAR/330BAR optional.
¡ñIntegrated refrigeration dryer optional.
Model | Driven | Charging Rate l/min | Pressure Bar | Filling valve | Control | Dimensions mm | Weight kg |
HX235ESC | 380/3/50 4KW | 235 | 225/330 | 2 | C | 1100*720*1365 | 260 |
HX300ESC | 380/3/50 5.5KW | 300 | 225/330 | 2 | C | 1100*720*1365 | 267 |
HX345ESC | 380/3/50 7.5KW | 345 | 225/330 | 2 | C | 1100*720*1365 | 272 |
HX385ESC | 380/3/50 7.5KW | 385 | 225/330 | 2 | C | 1100*720*1365 | 273 |
HX450ESC | 380/3/50 11KW | 450 | 225/330/400 | 4 | C | 1400*850*1660 | 490 |
HX550ESC | 380/3/50 11KW | 550 | 225/330/400 | 4 | C | 1400*850*1660 | 490 |
HX650ESC | 380/3/50 15KW | 650 | 225/330/400 | 4 | C | 1400*850*1660 | 500 |
HX750ESC | 380/3/50 15KW | 750 | 225/330/400 | 4 | C | 1400*850*1660 | 500 |
1.1.Charging rate is measured by cylinder(10L)from 0-200Bar,+/-5%. 2.C control is PLC control with touch screen |