Breathing Air Compressors

High Air HX series breathing air compressor is designed to be reliable, durable, easy to maintain, and energy-efficient. It finds wide applications in firefighting, diving, personal protection, and rescue fields.¡£

For different applications, we can provide flow ranging from 80L/min to 2800L/min, with a maximum filling pressure of up to 400 BAR. We offer both portable and silent compressors for inflation stations, along with containment fill station, control panels, gas storage systems, and testing systems, catering to your diverse needs. Our goal is to provide you with a one-stop solution to meet all your requirements.

The quality of breathing air directly affects the health of the users. We ensure that every compressor is equipped with an air purification system, and the quality of the outlet air meets and exceeds the EN 12021 breathing air standard. This guarantees that we provide you with clean and safe air, ensuring the well-being and safety of the users.


EN 12021:2014REQUITMENTS
Oxygen(O2)21%Ê¿1%
Carbon monoxide(CO)15ppm
Carbon dioxide(CO2)500ppm
oi0.5mg/m3
H2O25mg/m3


Portable Breathing Air Compressors

The HX125 series portable breathing aircompressors,compact structure, strong durability, light weight, easy to move, widely used in the fields of firefighting, diving, and rescue.

¡ñ Steelbase-plate, high -strength ABS belt protective  cover, providing all-round protection.

¡ñ Arc-shaped handle, easy holding and carrying.

¡ñ Motor and gasoline driven optional.

¡ñ Three-phase motor version with a magnetic starter  and pressure switch,    auto stop.

¡ñ The motor driven with 3 meters power line, industrial  plug and socket, hat is, plug and play.

¡ñ The gasoline engine driven has an extended intake  pipeline to prevent  gasoline engine emission pollution.

¡ñ Three-stage design block, with stainless steel coolers.

¡ñ Over sized breathing air filter to meet breathing  standards EN12021.

¡ñ 225BAR/330BAR optional

¡ñ Pressure maintaining valve.

¡ñ One filling valve with pressure gauge.

                         


ModelDrivenCharging Rate   l/minPressaure  Bar
Filling  valveDimensions  mmWeight    kg
HX125E380/3/50 3KW motor125225/3301
706*376*43249
HX125M220/1/50 3KW motor125225/3301706*376*43252
HX125G5.5HP gasolinel Engine125225/3301706*408*43247
Charging rate is measured by cylinder(10L) from 0-200Bar+/-5%.


¡ñ Steelbase-plate, high-strength ABS belt protective cover,   providing all-round protection.

¡ñ Arc-shaped handle, easy holding and carrying.

¡ñ Motor and gasoline driven optional.

¡ñ Three-phase motor version with a magnetic starter and  pressure switch, Auto stop

¡ñ The motor driven with 3 meters power line,  industrial plug and socket, that is, plug and play.

¡ñ The gasoline engine driven has an extended intake pipeline to prevent gasoline engine emission  pollution.

¡ñ Three-stage block, with stainless steel coolers.

¡ñ Over sized breathing air filter to meet breathing standards EN12021.

¡ñ 225BAR/330BAR optional.

¡ñ Pressure maintaining valve and check valve.

¡ñ Two Filling valves with hoses.


                  



ModelDrivenCharging Rate  l/minPressure   BarFilling  valveDimensions  mmWeight  kg
HX235E380/3/50 4KW motor235225/3302975*508*700
118
HX235M220/1/504KW motor235225/3302975*508*700122
HX235G9.5HP gasoline engine235225/33021065*508*700123
HX300E380/3/505.5kW motor300225/3302975*508*700125
HX300G9.5HP gasoline engine300225/33021065*508*700128
HX345E380/3/50 7.5KW motor345225/3302975*508*700130
HX345G9.5HP gasoline engine345225/33021065*508*700128

1.Charging rate is measured by cylinder(10L) from 0-200Bar,+/-5%.

2.Gasoline engine driven is manual control.

3.Handles are not included in the dimensions.The length is 1250mm with handles.


Integrated Breathing Air Compressords

¡ñ High strength aluminum alloy frame, ABS belt protective  cover, providing all-around protection.

¡ñ Arc-shaped handle, easy holding and carrying.

¡ñ Motor and gasoline driven optional.

¡ñ Automatic condensate drain and sewage collection system, Clean and environmentally friendly.

¡ñ Different control systems optional  B-Electric control,with pressure switch ,auto stop.C-PLC control,with pressure sensor,auto start/stop.

¡ñ The motor driven with 3 meters power line, industrial plug and  socket, that is, plug and play.

¡ñ The gasoline engine driven has an extended intake pipeline to prevent gasoline engine emission pollution.

¡ñ Three-stage design block, with stainless steel coolers.

¡ñ Over sizedd breathing air filter to meet breathing standards EN12021.

¡ñ 225BAR/330BAR optional.

¡ñ Pressure maintaining valve and check valve.

¡ñ Two Filling valves with hoses.

¡ñ Wheels optional.


                                                   


ModelDrivenCharging Rate  l/minPressure   BarFilling  valveControlDimensions  mmWeight  kg
HX235ET380/3/50 4KW motor235225/3302B/C1228*593*714126
HX235MT220/1/50 4kW motor235225/3302B/C1228*593*714130
HX235GT9.5HP gasoline235225/3302Manual1228*593*714123
HX300ET380/3/505.5KW motor300225/3302B/C1228*593*714133
HX300GT9.5H gasoline300225/3302Manual1228*593*714123
HX345ET380/3/50 7.5kW motor345225/3302B/C1228*593*714138
HX345GT14HP gasoline345225/3302Manual1228*593*714128
HX385ET380/3/50 7.5KW motor385225/3302B/C1228*593*714140
HX385GT14HP gasoline385225/3302Manual1228*593*714130

1. Charging rate is measured by cylinder(10L) from 0-200Bar+/-5%.

2. Gasoline engine driven is manual control.


Silent Breathing Air Compressors

¡ñVertical design, small footprint.

¡ñSuper silent design, noise lever less than 70dBA.

¡ñAutomatic condensate drain and sewage collection  system, Clean and environmentally friendly. 

¡ñAutomatic PLC control system with touch screen.

¡ñFilling port for cylinder groups filling with valve optional.

¡ñOver sized breathing air filter to meet breathing standards EN12021.

¡ñ 225BAR/330BAR optional.

¡ñIntegrated refrigeration dryer optional.

                                           

ModelDrivenCharging Rate  l/minPressure   BarFilling  valveControlDimensions    mmWeight  kg
HX235ESC380/3/50 4KW235225/3302C1100*720*1365260
HX300ESC380/3/50 5.5KW300225/3302C1100*720*1365267
HX345ESC380/3/50 7.5KW345225/3302C1100*720*1365272
HX385ESC380/3/50 7.5KW385225/3302C1100*720*1365273
HX450ESC380/3/50 11KW450225/330/4004C1400*850*1660490
HX550ESC380/3/50 11KW550225/330/4004C1400*850*1660490
HX650ESC380/3/50 15KW650225/330/4004C1400*850*1660500
HX750ESC380/3/50 15KW750225/330/4004C1400*850*1660500

1.1.Charging rate is measured by cylinder(10L)from 0-200Bar,+/-5%.

2.C control is PLC control with touch screen